Instructor:    Dan Beert

 

ASSIGNMENT #6: Building Sections & exterior elevations

 

Building Section

 

1.         Media: lead on vellum titleblock sheets. One section drawing will be drawn at 1/4”=1’-0” scale. Find the section symbol on the floorplan handouts for section 1/A3.2. This corresponds with the section view on your handout that you will draw. This assignment requires information from the floor plans and handouts.

2.         You will measure the handouts at 1/8” scale to the nearest 1” increment.

3.         Because this is a DESIGN section, and not a CONSTRUCTION section (see Ching pp. 36, 55-63). Therefore, the construction details seen in the handout’s section drawing will not be shown.

4.         In a design section, things like the juncture of the foundation, the floor structure, and the wall will only be profiled: Items cut in section will appear darker than those beyond. A design section focuses on the volume of interior space and the shape and openings of the interior/exterior enclosure.

5.

EXTERIOR

 
         The finished floor lines for each floor shall be shown on the drawing by using an elevation datum symbol. Included with each is the floor name, and elevation relative to the first floor line (which is referenced as 0'-0"). (See notes on p. 3) EXAMPLE: The 1st Floor elevation datum symbol aligns with the finished floor and will appear (something) like this (see linetype handout: centerline style):

 

 


         

 

 


6.         The roof pitch shall be indicated (See notes on p. 3). Dimension the width of roof overhang. Find the most detailed drawing of the overhang. Use this dimension.

7.         Show all footings in the section view. Rafters, joists, and insulation will not be shown in the section view, since it is a design section. However, you will show the roof truss seen in this section view.

8.         Room names and numbers are typically indicated in rooms on the building sections. Place these so they do not obstruct any more than necessary.

9.         The section shall be titled using standard drawing title conventions (See p. 3).

10.       Draw building section cut symbol on the original vellum floor plans as shown on the originals, and add numbers: 1 / A4: 1 goes above, A4 in bottom of circle.

Exterior Elevations

 

1.            Two exterior elevations will be drawn at 1/4”=1’-0”. One on the same sheet as the section view, and the other on a separate sheet. The South Elevation corresponds with Section AA (1/A4) and will be drawn alongside it on the same sheet (Sheet A4). The West Elevation will be drawn on its own sheet (Sheet A3).

 

2.            Arrange Sheet A4 so that the South Elevation is to the right of the section view.  Place the drawings so that the floor lines align with each other and so that there will be adequate space between the drawings to allow for notes and dimensions (see page 3 of handout). Balance the drawings on the sheet so that there is more space below the drawings than above them. This is because the drawing titles will be placed below, and there may be additional notes below, as well.

 

3.            Arrange the West Elevation on Sheet A3 so that it is in the same approximate vertical location on the sheet as the drawings on Sheet A4.

 

4.            Several line types will be used to produce the elevation drawings. Thick profile lines for the outline of the elevation and grade (ground) line, and thin, crisp lines for entourage: representation of specific materials (i.e. the roofing material, wood siding, etc.). Refer to the Ching and Yee books for examples of how to draw convincing representations of building materials.

 

5.            Roof material and overhang profiles should correspond with the most detailed information contained in the handouts. Typically, the most detailed views are drawn after the overall views because that is when the actual construction methods are decided on. This means that some information in the handouts may be different than what’s shown on the elevation views.

 

6.            Door and window locations and widths should correspond to your floor plan and sections. Show door and window heights as indicated in the section/elevation handouts.

 

7.            Entourage for the exterior wood sheathing should be on the back of the vellum. Render glazing (glass) as a tone pattern using lines (suggestions: Ching pp. 132, 142, 170), also on the back of the vellum.

 

8.            The foundation is hidden below grade, and should be represented by long dashed lines. The foundation should be drawn solid where it is exposed.

 

9.            The height dimensions and finished floor lines for each floor shall be shown on the elevation drawings by using datum symbols and alternating a (thin) long dashed line with a short dashed line, similar to note 5, page 1. Each line shall be titled. (i.e. “First Finish Floor Level” at 1/8” text height.)

 

10.       Include the notes listed on the following pages. All notes shall be aligned vertically on the sheet, flush left, at either side of the elevation. Use suggested note locations from drawings that will be posted in the studio.

 

11.       All drawings shall be titled. Use the compass direction to label the elevations. (For example “South Elevation.”) Use standard drawing title conventions.

 

REVIEW PINUP: Monday October 27, 2003
DUE:
Monday November 3, 2003

 

Annotation

Find these notes on the handouts and place them on your drawings in an appropriate location. It may be that you can find a better location for them than what is shown on the handouts, or that you will require more (or less) lines of text to write the same note. NOTE: Some notes have been excluded.

In capital letters, below, are the notes; in parentheses and italics, notes and comments on location, etc.

Section AA
(place the number 1 in the drawing label circle and use the drawing title: SECTION AA)

  1. Elevation Datum Symbols
    (Arrange so that they are between and shared by Section AA and South Elevation.)
    FIRST FLOOR               +0’-0”
    SECOND FLOOR          +10’-0”
    T.O. PLATE                   +20’-0”              (top of plate is top of whale bone elements)
    RIDGE                          +28’-0”
    T.O. CHIMNEY              +30’-0”              (top of chimney)
    (These should be arranged so that they are between and shared by two adjacent drawings.)
  2. Roof Slope Symbol
    1/8” text height

Overall: symbol is no longer than 1”




Notes:

  1. 1X6 CLR. CEDAR T&G CEILING
  2. (2) 4X10 BEAMS BOLTED TO WHALE BONES & SHAPED 4X12 SPLICE @ CENTER
  3. AWNING (N.I.C.)
  4. COPPER CAP
  5. 6X12 ROUGH HEWN MAPLE MANTEL
  6. DRYGROUT STACKED BASALT FIELDSTONE VENEER OVER 2X FRAMING (on Sect. CC @ top of chimney; find similar location)
  7. SHAPED COPPER CAP (on Sect. CC @ top of chimney; find similar location)
  8. Add room names AND room numbers as on plans.

Drawing Titles

  1. Label as: Section AA. Change scale to read exactly:  SCALE: 1/4"=1’-0”
  2. Always number according to order on the page: left to right, then top to bottom.

South Elevation

Notes may appear on other elevations. Find best corresponding location on this elevation.

  1. HORIZ. 1X4 CEDAR T&G SIDING
  2. PAINTED WOOD FASCIA W/PAINTED MTL. GUTTERS
  3. STAINED WOOD BEAMS
  4. 1X12 CEDAR ACCENT BAND (TIGHT KNOT) TRANSLUCENT STAIN
  5. HORIZ. LAPPED COPPER SIDING
  6. VERT. 1X4 TIGHT KNOT CEDAR TONGUE & GROOVE SIDING W/ TRANSLUCENT STAIN
  7. VINYL WINDOW SYSTEM
  8. WOOD & METAL AWNING (N.I.C.) (note appears at bottom of drawing)
  9. DRYGROUT STACKED BASALT FIELDSTONE VENEER OVER 2X FRAMED BOX

In capital letters, below, are the notes; below them, the elements that are referenced in the notes.

West Elevation

  1. ASPHALT COMPOSITION SHINGLE (this appears on the EAST elevation; place here instead)
  2. COPPER SIDING
  3. LAPPED COPPER AT RECESS
    at reveal on face of NOOK enclosure
  4. STAINED WOOD BEAMS
    projections at top of chimney
  5. HORIZ. LAPPED COPPER SIDING
    chimney finish
  6. METAL & WOOD AWNING (N.I.C.)
    suspended over French doors
  7. COPPER CAP
    top of stone fireplace surround
  8. DRY GROUT STACKED BASALT FIELDSTONE VENEER OVER 2X FRAMED BOX
    fireplace surround